Online Safety Relief Valve Testing
- Zero Shutdown
- Ex Approved
- Spring Loaded SRV only
- Powerbox with electric driven hydraulic pump.
- 10 m hybrid cable, completed with heat shield.
- PreVenTest bracket, with three hydraulic cylinders with attached load transducer.
- Ruggedized laptop computer with PreVenTest software pre-installed. Dual battery with hot swap feature.
- 3 x rigid suitcase with bracket, cylinders, transducers, accessories and power box.
- ATEX Certification
- Intrinsically safe PreVenTest Advance is designed for use in zone I and II with ATEX certification. Standard laptop is replaced by ATEX certified Ruggedized Tablet Computer.
- 50 kN Pulling Bracket – Including calibrated load cell, cylinder and large spindle adapter. For testing larger Pressure Safety Valves or testing at a low line pressure or ‘cold testing’ without line pressure.
- Spindle nut adapter set – Metric (Including Nut case with 15 nuts: M6x1; M8x1,25; M10x1,5; M12x1,75: M14x2; M16x2; M18x2,5; M20x2,5; M22x2,5 M24x3; M27x3; M30x3,5; M33x3,5; ø 30 blind; ø38 blind)